34563 Fixed bug where only the low byte of a value was written.
34728 Fixed an error that could occur when loading tags from the .dynJobs file.
34151 An error caused by receiving float values with unreadable formatting has been fixed.
34123 An error caused by reading a boolean array with an address other than a multiple of 8 has been resolved.
34338 Fixed the error caused by trying to add the SQLDriver driver to a database stored project.
35111 Eliminated a memory consumption that was caused by sending system messages.
33924 Redundancy 3 In a Redundancy system a Client could not switch back to the available Server.
34069 DeployServer 4 Password requirements were validated only once, even if the password was changed.
34135 Drivers 4 Fixed an error that blocked the use of the same element of two different structures on two different state variables (of driver, station or channel).
34263 Fixed the behavior of the alarm sound during the shelved time.
35067 Fixed a bug that caused communication to hang after an incorrect response.
34350 Fixed an error generated by Boolean tags read using 'Element Number'.
34215 An error caused by reading a string type tag with 'Element Number' other than 0 has been resolved.
33689 Fixed an issue where timestamp kept updating.
33706 If a good quality '(null)' value string is received, the tag value is forced to an empty string ("").
34610 Fixed a bug that, if you enable "Enable polling reading" in the station, causes the read data to be published even if it does not change.
33714 The assignment of stations with identical selection parameters to the same channel has been blocked.
34515 Eliminated the creation, caused by the connection test, of the .tia and .dynJobs files in the project.
33978 Fixed an issue where active tags are invalid for a few seconds when writing a value to a tag.
34105 Read and write operations have been speeded up.
34142 Fixed bug that blocked reconnection to primary host once backup host connected.
34333 Better handling of Sequence Number SID errors.
33806 Datalogger recording started only after recording time has fully expired.
30986 The server startup could be slow in certain situations.
12154 Starting two instances of Movicon in rapid succession generated an error when starting a windows service.
34884 It was not possible to connect to OPC UA Servers having key sizes smaller than 2048 bytes
34385 Some problems could occur when running more Logic or Script Services of different projects on the same machine.
33980 Fixed an issue that blocked the transmission of string type recipe items if the value field was not populated.
34403 Redundancy 4 In Redundancy the connection string of a Report didn't switch to the active server DataBase.
23029 Redundancy 4 In Redundancy a Client replaced the host name in the connection string to the DB even if it was not (local).
34395 Redundancy 4 For the alarm window, on two servers in redundancy, alarm sound didn't work correctly.
34302 Redundancy 4 A tag could remain connected to the localhost I/O server even when it was stopped.
33741 Fixed failed valorization of the Advanced Gauge, if the value of the tag was changed in another screen.
31888 The Option Button didn't work correctly if the screen was set as "Keep always in memory".
34153 For DataAnalysisRT, an error occurred with the customer project when the pen Statistics properties is enabled on a tag.
30650 For DataAnalysisRT, Y axis was not shown if in the pen name there is a special char.
34330 The DataAnalysis object could slow down the user interface a lot in case of many points displayed on the graph.
34250 Some animations could not run correctly on clients in a redundant system.
34570 Child Project: In some cases symbols were not displayed correctly in child projects.
33802 Starting the project in GeoMap mode the screens could not be positioned correctly on the map.
29762 Opening a Popup screen could not be done on the monitor of the calling screen.
29811 A symbol inserted as a drop-link in a screen did not update the container but only the sub-elements.
34416 Tools 4 It was not possible to use the + character within the deploy server connection password.
34298 The Screen loading could take a long time with User Management active and a Server Connection in error.
34362 Users: there were problems updating users with shared repository and its backup, in case of network connection problems.
34361 Users: if present, the shared repository backup was not kept aligned at runtime.
34722 Users: Shared repository, sometime a useless self linked server was created.
34364 Users: Shared repository, sometimes linked servers were created with the wrong instance name.
34865 Users: In some circumstances the SharedRepository and its backup remained misaligned.
33920 On WebHMI, opening the Numeric Pad, the decimals were not displayed.
33829 On WebHMI the MoveX and MoveY animations on grouped objects did not working anymore.
33146 Fixed anomaly during applying time window to filter data on the DART with fetch command.
34229 Workspace: the Discovery certificates were no longer created with Local Discovery Service 1.04.
32841 By pressing the Enter key the property window could appear when it was not necessary.
33132 In design the MoveX and MoveY animations could be applied permanently to the object when Animation Time was set to 0.
32022 Pop-ups opened on the secondary monitor were positioned incorrectly in case monitors have a different resolution.